Application Of Gas Detector
Application Areas Of VICTORY GT-07
LPG Cylinder Bank
Commercial Kitchen
LPG Gas Bank
Pantry Car
Details
When any combustible gas like LPG, petroleum vapour, Hydro Carbons, Carbon Monoxide, Spirit fumes is in the air the instrument give our Audio Visual Alarm. GT-07 is a sturdy equipment housed in a shock proof, weather resistant enclosure for monitoring combustible Gas and active alarm circuit when the concentration exceeds threshold limit. The instrument utilizes solid state platinum sensor for detection of combustible gas.
Gas Detected : Combustible and explosive Gases like LPG, Methane Town Gas, Coal Gas, Natural Gas, Hydrogen, Propane, Butane
Sampling Method : Automatic Diffusion
Principle : Catalytic Combusting Method
Sensor : Exd 11 B T6 65 (Central Mining Research approved)
Indication : Wait, Ready, Alarm and Power
Response Time : <2 Sec
Power (Unit) : 220V AC 50HZ, 2 Watts
Power Sensor : 5V DC (from Panel)
Operating Temperature Range : -10° to +70°C
Humidity (Operating) : 5 to 95% (NON Condensing)
Dimension : 210mm x 130mm x 50mm
Weight : 500gms
Range : 0-100% LEL
Alarm Set : Factory set at 20% LEL
- Hotel
- Restaurants
- Hospital
- Railways
- Commercial Kitchen
- Defence
- Industries
- Laboratories
Application Areas Of VICTORY GT-01
Details
Victory GT-01 Gas Detector is for LPG, Piped Gas, Town Gas, Natural Gas, Coal Gas. We are sure you will find GT-01 a very user friendly equipment which has been designed to give trouble free services for a long time.
Gas Detected : Combustible/explosives gases like LPG, Methane, Town Gas, Coal Gas, Natural Gas, PNG
Detection Range : 0 -100% LEL (Lower Explosive Limit)
Operating Temperature : 0°C to 70°C
Warn / Alarm Functions : Audible alarm provided on each model
Alarm Set Points : 10% of LEL (LPG 2.2% = 100% LEL)
Humidity (Operating) : 5 to 95% (Non Condensing)
Response Time : 15 Sec. at 90% response
Principle : Catalytic combustion method
Sampling Method : Automatic Diffusion/Aspirator
Indication : WAIT, READY, ALARM
LP Gas Banks, CNG Gas Banks, Restaurants, Hotels, Clubs, Industrial Kitchens, Office Kitchens, laboratories, Defence Factories, LPG stations, Pantry Cars, LPG Rooms, LPG Godowns etc.
Application Areas Of VICTORY GT-18A
Details
To detect any combustible gas like LPG, PNG, CNG Petroleum vapour, Hydro Carbons, Carbon Monoxide, spirit fumes in the air to gives
audio visual alarm. The Gas Detector Model GT-07 is sturdy equipment housed in shock proof, weather resistant PESO approved sensor
for monitoring combustible gases and activate alarm when the concentration exceeds threshold limit. The instrument utilises solid
state sensor for detection of gas.
Gas Detected : Combustible/explosives gases like LPG, Methane, Town Gas, Coal Gas, Natural Gas, PNG
Detection Range : 0 -100% LEL (Lower Explosive Limit)
Power (Sensor) : 12V only from panel (Main unit)
Operating Temperature : 0°C to 70°C
Warn / Alarm Functions : Audible / Visual alarm provided
Alarm Set Point : 10% of LEL (LPG 2.2% = 100% LEL)
Humidity (Operating) : 5 to 95% (Non Condensing)
Dimension : 115 mm x 115 mm x 90 mm
Weight : 500 gm
Response Time : 2 Sec. at 90% response
Principle : Catalytic Combustion Method
Sampling Method : Automatic Diffusion
Indication : Wait, Alarm, Power
CMRI Approved : Exd IIB T6 IPSS
LP Gas Banks, CNG Gas Banks, PNG, Restaurants, Hotels, Clubs, Industrial Kitchens, Office Kitchens, laboratories, Defence Factories, LPG Vaporizer Rooms, Pantry Cars, LPG Rooms, LPG Bullets etc.
Application Areas Of VICTORY V-205
Details
ELECTRONIC GAS DETECTOR/MONITOR Stationary Application/ BAR Graph Display
Gas detected : Combustible
Detection Range : 0-100% LEL (Lower Explosive Limit)
Power : 220V AC 50/60Hz 2 Watts
Operating Temperature :-5 degree to 70 degree C
Warn/Alarm Functions :Audible Warm and Alarm Relays are provided on each madel
Relay Contact Ratings : 3 AMP 240V AC (Resistive Load)
Warn/Alarm Set Points : User Selectable (10-100%)
Humidity (Operating) : 5 to 95% (Non Condensing)
Suitable for all combustible Toxic gases : (to be specified while ordering)
Dimension : 200 X 130X 60 mm (approx)
Weight : 2 kg appr.
Response Time : 15 Sec. at 90% response
Used for detection of Combustible Gas and to give easy to read BAR GRAPH indication proportional to the leakage, for easy interpretation. 2 alarm points can be set (Low to High) by user.
Application Areas Of VICTORY V-205DEX
Details
ELECTRONIC GAS DETECTOR/MONITOR (Fixed Installation Gas Detector/Monitor)
Description:
Victory 205DEx is a sturdy equipment for detection of toxic/combustible gases. Housed in a shock proof, weather-resistant enclosure for monitoring and activate alarm when the concentration exceeds threshold limit. The unit displays the concentration in PPM or LEL. Alarm be set by user from 0 to 00% range. The basic console can be supplied with fixed or remote sensor and explosion proof enclosures (PESO Approved).
Gas detected : Combustible/Toxic (to be specified)
Detection Range : 0-100% LEL (Lower Explosive Limit or PPM)
Power : 12V/24V
Operating Temperature :-5 degree to 70 degree C
Operating Voltage : +12V DC
Output : Potential free relay output
Warn/Alarm Functions : LED and Buzzer and relay are provided on each model
Relay Contact Ratings : 3 AMP 240V AC (Resistive Load)
Alarm Set Points : User Selectable (full scale)
Humidity (Operating) : 0 to 95% (Non Condensing)
Dimension : 180 X 150X 75 mm
Weight : 2 kg appr.
Response Time : 5 Sec. at 90% response
Sensor : Catalytic combustion method/elctro chemical cell
Range : 0-100% LEL
Panel Compatible with : V-2000, V-4000
IP Grade : IP-66
In Defense factories, Petrochemical Complexes, LPG stations, Railways, Hotel/Gas Banks.
Application Areas Of VICTORY V-700
Details
Gas detected :Single/Multi Gas/Combustible/ Toxic or combination.
Response Time :T90<30s
Indication :LCD Indicates real time and system stat
Alarm Indication :Wide-angled light emitting diode. 85db buzz (the frequency of buzz depends the density), vibrating.
Fault Indication : Indications of Zero point drift and sensor failure.
Operating Temperature : -30° to +50
GAS : CH4, 02, NH3, H2S, CO, C2H2 etc, as required /LEL/PPM
Sampling Pump : Battery operated programmable (optional)
Humidity : <95% RH non-condensing
Voltage : DC3.7V Li-on battery 1200mAh
Charging Time : 4hrs to 6hrs
Duration of Operation : Flammable gas Binon-stopped) hrs/Toxic gas <300h (non-stopped) hrs
IP Grade : IP 66
Weight : About 120g (including battery)
Dimension : 102mm X 56mm X 26mm
The detector monitors the gas density and is widely used in tanks, confined spaces, factories underground pipes ett. effectively prevents accident and adopts.
Application Areas Of VICTORY V-9000
Details
SPOT GAS DETECTOR:
(Fixed Installation Gas Detector / Monitor)
V9000 series online gas detector uses the solid state sensor and the ultra low power 32 bit microprocessor, so with the advantages of high precision, good repeatability, stable signal, respond quickly, etc. Possible connected with many controller system, such as PLC, DCS, computer and other, with the function of remote monitor and alarm, data logger and analysis.
FEATURES:
1. 4-20mA standard analog signal and RS485 digital signal output, relay output.
2. LED screen displaying the gas concentration, gas type, unit, Instrument status, etc.
3. Independent air chamber, the sensor is not required to replace the sensor calibration, automatic identification of key parameters of the sensor.
4. Protection function to prevent high gas concentration attack.
5. Display the gas concentration in ppm or LEL.
6. Infrared remote controller operation.
7. With the 18bit ADC acquisition chip, designed with four-layer circuit board, so with high anti-Interference ability.
8. With the ex-proof certificate, the ex-proof grade is Exd II CТ6.
Applicable Gas : Combustible/Toxic
Detecting Range : LEL/PPm
Resolution : 1% or 1PPm
Sampling : Diffusion or pump-suction, circulation selectable
Accuracy : ≤3%F.S
Repeatability : ≤1%
Zero drift : ≤1%(F.S/ year)
Sensor Type : Electrochemical sensor/Solid state
Sensor Life : 2-3 years
Response Time (T90) : ≤20s
Alarming mode : Audio-visual alarm (Optional)
Operating Environment : Temperature: -30°C ~ 60°C (Customized for special demands)
Humidity: ≤95%RH (non-condensing); If >90%RH, can add the filter
Pressure: 86kPa ~ 106kPa
Working Voltage : 24V DC (16~30VDC)
Output Signals : (Standard) Three-wire system 4~20mA standard signals output, available for PLC,DCS, etc;
(Optional) Four-wire system RS-485 digital 5 digital signal output;
Two-level relay output: 220VAC 0.5A, SVDC 0.5A
Installation Means :
Wall mounted, Pipe type(Thread: M40*1.5)
Material of Body : Cast aluminum LM-6
Explosion-proof Index : Exd IIC T6
Protection Grade : IP66
Electrical Interface : 3/4"NPT Female Screw), 1/2" NTP(Female 5crew)
Transmit Distance : ≤2000m (RS485)
Dimension : 210mm C 140mm X 92mm (L x W x H)
Weight : about 1.5 kg
Warranty : 12 months
PESO : Approved
Common applications is gas safety inspection and alarm for industrial scene such as petroleum refinery, chemical plants, LPG stations, boiler rooms, gas stations, paint spray booths, metallurgy, mining, fire, environmental protection etc. where need to inspect the gas concentration.
Application Areas Of VICTORY V-5000
Details
SPOT GAS DETECTOR:
(Fixed Installation Gas Detector / Monitor)
Detecting Gas :Combustible gas(PNG/LPG/CNG)/Toxic/oxygen
Sensor Type :Catalytic combustion type/Electro-chemical
Detection Method : Diffusion
Measuring Range :(0~100)% LEL/ppm
Alarm Setting : 1-100%
Alarm : Audio and visual alarm (2 x Relay)
Audible Alarm Level : ≥80dB
Output : 4~20mA signal
Response Time : T90≤10s
Operating Voltage : 12V/24V DC
Temperature : -10°C ~ +55°C
Humidity : <95%RH (No Condensation)
Display : 16 x 2 LCD display, Power LED
For Spot gas detectors & Indicator of Combustible/Toxic/Oxygen gases in any application.
Application Areas Of VICTORY VP
LPG Pipeline
Details
Pen Type Portable Combustible Gas Detector (LPG, Natural Gas, Methane, CNG)
Operating Temperature : 20° +55° C
Operating Humidity :<95%RH
Operating Voltage :DC3V (2x1.5V AA ALKALINE batteries)
Low Alarm :(20 + /-5) % RH
High Alarm :(50 +/ -10) % LEL
Response Time :<5s
Alarm Method :Visual & audible alarm
Sound :>=65Db
Body :Stainless steel20° +55° C
Detecting Gas :Natural Gas, LPG, H2, and Combustible / Explosive gas.
Range :0-100%
Sampling :Natural diffusion