GAS DETECTORS

Application Areas Of VICTORY GT-07


LPG Cylinder Bank

Commercial Kitchen

LPG Gas Bank

Pantry Car

  • ELECTRONIC GAS DETECTOR

    VICTORY GT-07

When any combustible gas like LPG, petroleum vapour, Hydro Carbons, Carbon Monoxide, Spirit fumes is in the air the instrument give our Audio Visual Alarm. GT-07 is a sturdy equipment housed in a shock proof, weather resistant enclosure for monitoring combustible Gas and active alarm circuit when the concentration exceeds threshold limit. The instrument utilizes solid state platinum sensor for detection of combustible gas.

  • Gas Detected :Combustible and explosive Gases like LPG, Methane Town Gas, Coal Gas, Natural Gas, Hydrogen, Propane, Butane
  • Sampling Method :Automatic Diffusion
  • Principle :Catalytic Combusting Method
  • Sensor :Exd 11 B T6 65 (Central Mining Research approved)
  • Indication :Wait, Ready, Alarm and Power
  • Response Time :<2 Sec
  • Power (Unit) :220V AC 50HZ, 2 Watts
  • Power Sensor :5V DC (from Panel)
  • Operating Temperature Range :-10° to +70°C
  • Humidity (Operating) :5 to 95% (NON Condensing)
  • Dimension :210mm x 130mm x 50mm
  • Weight :500gms
  • Range :0-100% LEL
  • Alarm Set :Factory set at 20% LEL
  • Hotel
  • Restaurants
  • Hospital
  • Railways
  • Commercial Kitchen
  • Defence
  • Industries
  • Laboratories

  • ELECTRONIC GAS DETECTOR/MONITOR (Fixed installation Gas Detector/Monitor)

    V-205DEx

Model V-205DEx is a sturdy equipment for detection of toxic/combustible gases. Housed in a shock proof, weather-resistant enclosure for monitoring and activate alarm when the concentration exceeds threshold limit. The unit displays the concentration in PPM or LEL. Alarm be set by user from 0 to 100% range. The basic console can be supplied with fixed or remote sensor and explosion proof enclosures (PESO Approved).

  • Gas detected : Combustible / Toxic (to be specified)
  • Detection Range : 0-100% LEL (Lower Explosive Limit or PPM)
  • Power : 12V / 24V
  • Operating Temperature : -5 degree to 70 degree C /li>
  • Operating Voltage :+ 12V DC
  • Output : Potential Free Relay
  • Output Warn / Alarm Functions : LED and Buzzer and Relay are provided on each model
  • Relay Contact Ratings : 3 AMP @ 240V AC (Resistive Load)
  • Alarm Set Points : User Selectable (full scale)
  • Humidity (Operating) : 0 to 95% (Non Condensing)
  • Dimension : 180 X 150 x 75 mm
  • Weight : 2 kg appr.
  • Response Time : 5 Sec. at 90% response
  • Sensor : Catalystic Combustion Method / Electro Chemical Cell
  • Range : 0-100% LEL
  • Panel Compatible with : V-2000, V-4000

  • GAS DETECTOR

    GT-18

To detect any combustible gas like LPG, PNG, CNG Petroleum vapor, Hydro Carbons, Carbon Monoxide, spirit fumes in the air to gives audio visual alarm. The Gas Detector Model GT-07 is sturdy equipment housed in shock proof, weather resistant PESO approved sensor for monitoring combustible gases and activate alarm when the concentration exceeds threshold limit. The instrument utilizes solid state sensor for detection of gas.

  • Gas Detected :Combustible/explosives gases like LPG, Methane, Town Gas, Coal Gas, Natural Gas, PNG
  • Detection Range :0 -100% LEL (Lower Explosive Limit)
  • Power (Sensor) :12V only from panel (Main unit)
  • Operating Temperature :0°C to 70°C
  • Warn / Alarm Functions :Audible / Visual alarm provided
  • Alarm Set Point :10% of LEL (LPG 2.2% = 100% LEL)
  • Humidity (Operating) :5 to 95% (Non Condensing)
  • Dimension :115 mm x 115 mm x 90 mm
  • Weight :500 gm
  • Response Time :2 Sec. at 90% response
  • Principle :Catalytic Combustion Method
  • Sampling Method :Automatic Diffusion
  • Indication :Wait, Alarm, Power
  • CMRI Approved :Exd IIB T6 IPSS

Application Areas Of VICTORY VP


LPG Pipeline

  • Pen Type Portable Combustible Gas Detector

    VICTORY VP

Pen Type Portable Combustible Gas Detector (LPG, Natural Gas, Methane, CNG)

  • Operating Temperature :20° +55° C
  • Operating Humidity : <95%RH
  • Operating Voltage :DC3V (2x1.5V AA ALKALINE batteries)
  • Low Alarm :(20 + /-5) % RH
  • High Alarm :(50 +/ -10) % LEL
  • Response Time : <5s
  • Alarm Method :Visual & audible alarm
  • Sound :>=65Db
  • Body :Stainless steel20° +55° C
  • Detecting Gas :Natural Gas, LPG, H2, and Combustible / Explosive gas.
  • Range :0-100%
  • Sampling :Natural diffusion

  • DIGITAL GAS DETECTOR

    VICTORY 205D

VICTORY 205D is a sturdy equipment for detection of toxic / Combustible gases housed in a shock proof, weather resistant enclosure for monitoring combustible Gas and active alarm circuit when the concentration exceeds threshold limit. The instrument utilizes solid state platinum sensor for detection of gas. The unit displays the concentration in PPM or LEL. Alarm points are provided for indicating warning and alarm condition and they can be supplied with fixed or remote sensor and explosion proof enclosures. In use at Defense factories, Petrochemical Complexes, LPG Stations, Railway etc.

  • Gas Detected :Combustible / Toxic (to be specified)
  • Detection Range :0 – 100% LEL (Lower Explosive Limit/PPM)
  • Power :220V AC50 / 60 HZ 2 Watts
  • Operating Temperature :(10° to 70° C
  • Warn / Alarm Functions :LED and Buzzer for Relay are provided on each Model
  • Relay Contract Ratings :3 AMP @ 240V AC (Resistive load)
  • Warn / Alarm Set Points :User Selectable (full Scale)
  • Humidity (Operating) :6 to 95% (Non Condensing)
  • Suitable for Combustible & Toxic Gases :(To be specified while operating)
  • Dimension :200 x 130 x 60mm
  • Weight :2kg. appr.
  • Response Time :15 Sec. at 90% response
  • Sensor :Catalystic Combustion Method / Electro Chemical cell
  • Range :0 – 100% LEL / 0-2000 ppm.

  • 8 Channel Gas Detection Annunciation Panel

    V-2000

Model V-2000 is a 8 channel gas detection system which link in conjunction with GT-18. It is a compact unit with individual alarm unit along with digital read out of the zone name. The panel works on single face mains 220V AC has potential free relay output and sounder. The same model can be modified to give an output of 24 V Solenoid Valve or external alarm if require. The front panel has 3 buttons name as TEST, RESET & ACKNOWLEDGE.

  • Reliable and durable fixed life by the imported sensor.
  • Automatical Calibration and zero-set
  • Apparent and clear Display displaying real time and battery capacity, low battery indication
  • and automatic turn-off for low voltage
  • Advanced self-test of complete functions automatically when turn on
  • Alarm for sensor failure
  • Zone Display :Toxic/Combustible
  • No. of Channels : 0-100% LEL/ppm
  • Detector Power Supply : 1% VOL
  • Input Signal :<5s
  • Relay Output : Large LCD Indicates real time and system state
  • Audio-Visual alarm : Wide angled light emitting diode, 85db buzz (the frequency of buzz depends the density), vibrating
  • Working Temperature : Indications of Zero point drift and sensor failure
  • Working Humidity : -30˚ to +50˚ degree
  • Body Material : CH4, O2, NH3, H2S, CO, C2H2 & others
  • Installation Type : <95% RH non-condensing
  • Dimension : DC3, 7V Li-ion battery 1200mah
  • Weight : 4h to 6h
  • Warranty : flammable gas< 8(non-stopped); toxic gas <300h (non-stopped)
  • Solenied / Hooter output : IP66
  • Front Panel : about 120g (including battery)
  • ELECTRONIC GAS DETECTOR / MONITOR (Stationary Application) / Bar Graphic Display

    VICTORY 205

ELECTRIC GAS DETECTOR / MONITOR (Stationary Application) / Bar Graphic Display. In use at Defence factories, Petrochemical Complexes, LPG Stations, Railways etc

  • Gas detected :Combustible
  • Detection Range :0-100% LEL (Lower Explosive Limit)
  • Power :220V AC 50/60 HZ 2 Watts
  • Operating Temperature :-5˚ to 70˚ C
  • Sensor :Exd 11 B T6 65 (Central Mining Research approved)
  • Warn/ Alarm Functions :Audible Warn and Alarm Relays are provided on each model
  • Relay Contact Ratings :3 AMP @ 240V AC (Resistive load)
  • Warn/Alarm Set Points :User Selectable (10-100%)
  • Humidity (Operating) :5 to 95% (Non Condensing)
  • Suitable for all :(To be specified while ordering)
  • Combustible Toxic gases :
  • Dimension :200 x 130 x 60 mm (approx)
  • Weight :2 kg appr.
  • Response time :15 Sec. at 90% response

  • Gas Alarm Repeater Panel

    GT-18

Gas Alarm Repeater Panel


  • Gas Detection Panel

    Model-2000

Gas Detection Panel


  • Multizone Gas Alarm Panel

    GT-18

Multizone Gas Alarm Panel


  • Gas Detection Controller

    V-8000

Gas Detection Controller


  • MULTI-POINT GAS DETECTION PANEL FOR INDUSTRIAL USE

    MODEL - KB6000 III

KB6000 III is a sturdy equipment for detection of toxic / Combustible gases housed in a shock proof, weather resistant enclosure for monitoring combustible Gas and active alarm circuit when the concentration exceeds threshold limit.

  • Up to 30 points central monitoring
  • Intellectual system : Easy on-line zero calibration, relay free contact
  • Optional signal output of RS 485 (Modbus), suitable for DCS and PLC system
  • MCU control and abundant software : easy to complete signal sampling, real-time data calculating, system fault detection, power management, buttons scanning, displaying driving program, alarm displaying and linked external equipment etc.
  • Linked external equipment can automatically activate when meeting the preset logical program.
  • Linked external equipment can be activated through the controller
  • Intellectual management on all the gas detectors of different gas type, different detection range and different displaying units.
  • Main Power Supply :AC220V / AC110V 50Hz
  • Battery Backup :DC24V rechargeable Lead acid battery
  • Consumption :≤15W
  • Detector type :4-20mA and RS485 (Modbus)
  • Temperature :-10°C-50°C
  • Humidity :≤95%RH
  • Battery backup low voltage alert :DC22V±1V
  • Visual and audible alarm :-Lights show the working status
    -LED's show the alarming level or detector number
    -Different alarm sound show the alarming or fault alert
  • Cable requirement :RVVP4 X 1.5mm2
  • Transform distance :≤1000m
  • Relay output :Free contact 2A/AC220V
  • Dimensions :390 x 280 x 116mm (including the hanging plate)

  • SPOT GAS DETECTOR

    VICTORY V-9000

SPOT GAS DETECTOR

  • Detecting Gas :Combustible gas.
  • Sensor type :Catalytic combustion type for combustion gas
  • Detection method :Diffusion
  • Measuring method :(0~10/50/100)% LEL
  • Setting alarm :7% LEL for natural gas / LPG 100umol/mo/CO
  • Alarm method :Audible and visual alarm
  • Audible alarm level :>=80dB
  • Output control :The passive output of relay or shut-off valve output (optional)
  • Response time :T90<=30s
  • Operating Voltage :AC220V or AC110V + 15% ( as per different electric spec.)
  • Temperature :10˚ C~ +55˚ C
  • Humidity :<95%RH ( no condensation)

--------------------------------
  • VSPOT GAS DETECTOR

    VICTORY 5000

For Spot gas detectors & indicator of Combustible / Toxic / Oxygen gases in any application.

  • Detecting Gas :Combustible gas (PNG/LPG/CNG) / Toxic/ Oxygen
  • Sensor type :Catalytic combustion type / Electro-chemical
  • Detection method :Diffusion
  • Measuring range :(0 ~ 100)% LEL/ ppm
  • Alarm setting :1-100%
  • Alarm :Audio and visual alarm (2 x Relay)
  • Audible alarm level :>=80dB
  • Output :4 ~ 20mA signal
  • Response time :T90 < 10s
  • Operating Voltage :12 V / 24 V DC
  • Temperature :-10°C ~+ 55°C
  • Humidity :<95%RH (No Condensation)
  • Display :16 x 2 LCD display / Power LED

--------------------------------
  • DIGITAL ELECTRONIC GAS INDICATOR / DETECTOR

    VICTORY 700 ( HAND HELD)

When any combustible or Toxic gas like L.P.G., petroleum vapour, Methane, Chlorine, Ammonia, Hydro Carbons, Carbon Monoxide, spirit fumes in the air reach above a critical level, the instrument displays directly proportional to the concentration of the gas and gives audio visual waving to the user.

  • Industry
  • Corporation
  • Railways
  • Tank cleaning
  • Defence

Housed in an intrinsically safe enclosure & conforming to IS-5780/1980

  • Power Source :6 volt DC rechargeable batteries (Built in)
  • Battery Life :5000 Charging cycles (approx)
  • Autonomy (One charge) :1400 reading of 10 secs each
  • Power Consumption :170 MA
  • Operation Temperature :10 ° C to 70°C
  • Operation Humidity :5 to 95% Non condensing
  • Operation Range :0.0 to 100% LEL/ 0-200 ppm
  • Instrument Carrying Case :Provided
  • Principle : Catalytic Combustion method/Etectro Chemical Cell
  • Sampling Method :Automatic Diffusion
  • Accuracy :+5% of full scale
  • Response time :within 15 Sec. at 90% response
  • Audio Alarm :Electronic Buzzer
  • Gas : Combustible Toxic
  • Visual :LED
  • Gases :Methane / Oxygen / Ammonia / H2S / H2/ Co / C2H2 & Others.

  • HANDLE HELD GAS DETECTOR

    GT 01

Victory GT-01 Gas Detector is for LPG, Piped Gas, Town Gas, Natural Gas, Coal Gas. We are sure you will find GT-01 a very user friendly equipment which has been designed to give trouble free services for a longtime.

  • LP Gas Banks
  • CNG Gas Banks
  • Restaurants
  • Hotels
  • Club
  • Industrial kitchens
  • Office Kitchens
  • Laboratories
  • Defence factories
  • LPG Stations
  • Pantry Cars
  • LPG Godowns
  • LPG Room etc.
  • Gas Detected :Combustible/explosives gases like LPG, Methane, Town gas, Coal gas, Natural gas
  • Detection Range :0-100% LEL (Lower Explosive Limit)
  • Operating Temperature :0°C to 70°C
  • Warn / Alarm Function :Audible Alarm provided on each Model
  • Alarm Set Points :10% of LEL (LPG 2.2% = 100% LEL)
  • Humidity (Operating) :5 to 95% (Non Condensing)
  • Response time Principle :15 Sec. at 90% response : Catalytic
  • Sampling Method :Automatic Diffusion/Aspirator
  • Indication : WAIT, READY, ALARM

  • DOMESTIC GAS DETECTOR

    MODEL - V-201

When combustible gas like (Cooking Gas) Petroleum Vapour spirit fumes in the air reach above a critical level, the instrument will automatically operate to give audio visual alarm.

Home ( Kitchen, Ceiling etc.)

  • Housing as per :1P-20
  • Power source :220V
  • Frequency :50Hz
  • Power consumption :1W
  • Fuse capacity :2W
  • Operation temperature :10°C - 70°C
  • Operation Humidity :5 - 95%
  • Alarm Range :0.1 - 0.3% (Vol.)

BREATH ALCOHOL DETECTOR

  • ALCOHOL TESTER

    MODEL-2015
  • Equipment :Hand Held Breath Alcohol Detector
  • Sensor :Fuel Cell
  • Working Temperature :5°C to 50° C
  • Storage Humidity :95% RH at 40° C Non Condensing
  • Size :145 x 67 x 35 mm
  • Weight :< 600 gm
  • Number of Test :With fully Charged Battery 3s 500 Tests/ No Sample Data Under Low Battery Condition
  • Battery :Li-on, Battery Capacity of 1200 mAH
  • Response Times : - <10 Sec for Negative Result, < 30 Sec for Positive Result
  • Sampling System : Automatic or Manual Override
  • Unit of Measure :BrAC/ mg/L/ BAC: gm%/mg/ml/mg/ 100ml
  • Detection Range :0-400mg/100ml (User selectable)
  • Accuracy :+ 5% @ 80mg/100ml+
  • Memory :10,000 Test Records
  • Mode :Active/Passive
  • Audiovisual Indication :For All Parameters
  • Touch Screen Guided
  • Low Battery Indication
  • Screen Calibration Facility
  • Fields :Customizable (On Order)
  • Blow Duration and Pressure :Customizable
  • Mouth Piece :One Way Flow Round
  • Auto Switch off 

24 Column Wireless Dot Matrix Printer
  • a) Compact Size
  • b) Light Weight
  • c) Easy Load
  • d) Inbuilt Rechargeable Battery With Charger
  • e) Uses Plain Paper

  • FUEL CELL SENSOR BASED BREATH ALCOHOL ANALYSER CREW MANAGEMENT

    MODEL- VX-CMS
  • Crew Management System As Per RDSO 
  • Specification No.RDS0/2015/EL/SPEC/0119, 
  • (Rev '0') dtd.17.09.2015 
  • Sensor :Fuel Cell
  • Platform :LINUX/Windows
  • Mounting :As Required
  • Connectivity :Standard USB Cable
  • Communication :Bi Directional
  • Load :Capable of Conducting Minimum 500 Test/ 24 Hrs
  • Software :INCLUDED
  • Mouth Piece :One Way
  • Calibration :Annually
  • Weight : <400 gm
  • Other Parameters as per RDSO Specification.

  • BREATH ALCOHOL ANALYZER

    MODEL - V-1000
  • Evidential accuracy
  • Integrated fuel cell process
  • One way mouthpiece
  • Test record storage is high up to Quick response 2000 Test Record
  • Can interface with printer
  • Interface with PC
  • Menu driven test procedure
  • Self Test
  • Sensor :Fuel Cell
  • Working Temperature :- 10°C to 55°C
  • Storage Temperature :- 20°C to 70°C
  • Storage Humidity :<95%
  • Size :1750 x 70 x 35 mm
  • Weight:255g with batteries
  • Battery Life :Not less than 500 tests
  • Battery :4AAA alkaline batteries/Nimh
  • Display LCD size :50 mm x 35 mm
  • Response time : 5 seconds
  • Sampling System :Automatically or manually takes a lung sample
  • Units of Measure :BrAC: mg/L, or other units
  • BAC :grm%, mg/ML, mg/100m1
  • Detection Range :0.000 mg/L to 3.000 mg/L
  • Accuracy :0 to 0.100% BrAC 0.05%, 0.100 to 0.200% BrAC 5%, > 0.200% BrAC 10%
  • Memory:upto 2000 records
  • Measuring Modes :Active and passive
  • Optional Accessories :Dot matrix Printer, Rechargeable Battery, Charger
  • Unit comes complete with :Annually
  • Response time : Mains Adapter, One way mouth piece - 5 no., Blow pipe -1 no., CD containing software -1 no., USB cable -1 no., Printer cable -1 no., Carrying Case -1 no.

  • ALCOHOL TESTER

    MODEL - V-1100
  • Evidential accuracy Can interface with PC
  • One way mouthpiece Integrated fuel cell process
  • Quick response Test record - 10,000
  • Wireless printer Automated calibration
  • Menu driven test procedure
  • Sensor :Fuel Cell
  • Machine vvt.(without Battery) :240 gm
  • Battery :Four AA batteries (alkaline) / Rechargeable
  • External power supply :12VDC (Car Battery)/ or adaptor
  • Battery use life :Not less than 500 times (high quality AA type alkaline battery)
  • Response time :<25 seconds
  • Operating Temperature :- 10°C to 55°C
  • Relative humidity :No higher than 95% RH
  • Air pressure :86 Kpa to 106 Kpa
  • Storage Temperature :-20° -70°C
  • Testing bias :± 10% (Range: 0.400mg/1-1.000mg/1)
    ± 0.040mg/1(Range: 0.200mg/1-2 0.400mg/1)
    ± 0.025mg/1(Range: 0.400mg/11.000mg/1)
  • Testing range :0.00mg/1/1.00mg/1 (0.400mg/100m1)
  • Display :128x32matrix LCD screen
  • Printer output :wireless
  • Printer (Optional) :Dot Matrix 24 column
  • Complete Package :1. Instrument V-1100
    2. Printer (with built in rechargeable battery)
    3. Charger
    4. Printer
    5. One way Mouth Piece x 5 Nos
    6. Carrying case
    7. Instruction manual

  • BREATH ALCOHOL DETECTOR

    MODEL - V-7

BREATH ALCOHOL DETECTOR

  • Victory - V7 is a hand Breath Alcohol detector that reliably identifies alcohol impaired drivers.
  • Victory - V7 automatically tells you when its ready for the subject to take a test.
  • Quick measurement of the alcohol level is breath by highly sensitive sensor.
  • LCD display for immediate assessment.
  • Compact size and light weight makes it perfectly portable.
  • Size :145 x 60 x 25 mm ( + - 5mm)
  • Weight :300 gms. (approx)
  • Accuracy :2%
  • Batteries Operating :6V re - chargeable
  • Temperature :5°C to 50°C
  • Smoking Caution :Wait 3 minutes
  • Drinking Caution :Wait 5 minute
  • Audible alarm :Provided
  • LED Indication :Wait, Ready, Fail, Low Battery Charging.

  • BREATH ALCOHOL DETECTOR

    MODEL - V -701D

Breath alcohol detector with digital readout.

  • Victory - V701D is a hand Breath Alcohol detector that reliably alcohol identifies impaired drivers.
  • Its full featured design provides you with the objective, unbaised information you need and the easy operation you want.
  • Quick measurement of the alcohol level is breath by highly sensitive sensor.
  • LCD display for immediate assessment.
  • Compact size and light weight makes it perfectly portable.
  • Sensor :Solid State
  • Size :103 x 65 x 27 mm
  • Weight :200 gms.
  • Accuracy :+5%
  • Batteries :3X AAA Battery
  • Operating Temperature :0°C to 60°C
  • Purge Cycle :Automatic
  • Read Out :Immediate
  • Display :Four (4) digit bright LED
  • BAC Format :mg/100m1.

  • PROFESSIONAL BREATH ALCOHOL ANALYSER

    ALCOTORCH V1

Principle of operation through the blowing of breath into the fuel cell to determine whether the testee drunk alcohol or not.

Range of value applicable to different indicator

GREEN :<10mg/100mL
RED:>80mg/100mL
ORANGE: 10mg/100mL-80mg/100Ml

  • Sensor :Fuel Cell
  • Operating Temperature :0°C to 40°C
  • Size :265mmx48mm
  • Weight :330g
  • Battery :2,600mAh rechargeable battery
  • Detection Range :0.000%BAC TO 0.1000%BAC
  • Accuracy :distance with 5cm,+15%
  • Response Time :Normally with 3s of sampling
  • Recovery Time :2s at 0.00 mg/L, 20s at 0.50mg/L, 40s at 2.00mg/L
  • Warm-up Time :No warm-up time
  • Flashlight :Dual colour (Optional)
  • calibration Period :Half Year

  • BREATH ALCOHOL ANALYSER

    ALCOTORCH V2

BREATH ALCOHOL ANALYSER

  • Sensor :Fuel Cell
  • Measuring Mode :Quick Sampling, Auto Sampling
  • Pumping Mode :Continuous pumping, user can stop it during the test
  • Detection Range :0-400mL BAC
  • Sensitivity :0.5 mg/100mL BAC
  • Measuring Unit :mg/L(BrAC)or mg/100mL
  • Display :1.29"OLED colour display
  • Button :3individual button: Torch Control, Batch Control and\Alcohol testing button
  • Accuracy :Under standard concentration 50mg/100mL BAC: A.blowing distance<5cm:+5.0mg/100mL, B.blowing distance 5-10cm: +6.0mg/100mL, C. blowing distance > 10cm:+ 10.0mg/100Ml
  • Testing Time :1- 15 sec
  • Operating Temp. :0°C C to 50°C
  • Storage Temperature :20°C to 70°C
  • Room Temperature :-20°C to 98°C
  • Battery :18650 Lithium Battery: 4.35V/3000mAH,>500tests
  • Weight :245g(include battery)
  • Size :300mmx44mm
  • Power. :Alcohol Testing<50mA;Batch and Torch on
  • Torch features :Bright white, HIGH,LOW and FLASH
  • Power saving Mode :Under alcohol testing mode, it will shut down automatically, after 5 mins. Under Torch and Batch mode, this function is disabled

FIRE DETECTION

  • AUTOMATIC FIRE DETECTION AND EXTINGGUISHING SYSTEM

    VICTORY AFX(MODULAR)

  1. 1. Portable and Self contained.
  2. 2. Audible Alarm and Visual indication for all the parameters.
  3. 3. Robust and rugged housing for industrial and commercial uses.
  4. 4. Built in rechargeable Power Pack to function during power failure.
  5. 5. Manual Override Provision.
  6. 6. Solid State Sensors are utilized for detection of smoke/heat.
  7. 7. Systems available to operate on 220 VA/C, 12 VDC, 110 VDC.
  8. 8. Larger systems also available (please consult).
  9. 9. Vol. covered by one unit 1500 cu.ft.

  • Computer Room :Laboratories
  • Telephone Exchanges :Record rooms
  • MCC Rooms Godowns :Control Rooms
  • Godowns :Trasformers
  • Generators :CNC Machines C
  • Dimension :615x395x180 mm : 14 Kgs.
  • Weight of control panel :5 Kgs.
  • Quantity of Gas Alarm :Warbling 110 Db
  • Time Display Before Extinction :0-30 SEC. (Presetable)
  • Power Supply :220VAC (Standard) 12 VDC, 24 VDC (Optional)

  • AUTOMATIC FIRE DETECTION AND EXTINGUISHING SYSTEM CO2,FM200,FE227(FIXED)

Victory fire detection & extinguishing system has been designed for use where instant fire extinguishing is required. This is stand - alone operation system, the system automatically detects the fire and extinguishes it instantly.

The system is failproof and comprises of:
  1. 1. Control panel 2 zone with cross zoning facility.
  2. 2. Heat or Smoke detector x 2 nos.
  3. 3. Cylinder x 1 (45kg)
  4. 4. Frame & Activation device for Co2 Cylinder
  5. 5. Necessary discharge pipe and nozzles and hardware

  • Computer Room :Laboratories
  • Telephone Exchanges :Record rooms
  • MCC Rooms Godowns :Control Rooms
  • Godowns :Trasformers
  • Generators :CNC Machines C
  • Input Voltage :220 V AC
  • Auxiliary Power :24 V DC ( Battery)
  • Battery :12 V7AH X2
  • Power Consumption :Stand by 300 MA, Alarm 1.3 AMP
  • Alarm :95 db at 1 Mtr
  • Fuse Rating :1.5 AMP
  • Cable :1.5 SQ. MM. 2 Core Copper, Armoured / PVC
  • Lamp (Indicator) :LED's
  • Gas :45 Kgs.
  • Activation Mechanism :Electro Mechanical Device or Solid State
  • Number of Cylinder :(Optional) 1 - 20
  • Available with :FM 220, FE 227, Co2 (Carbon di oxide) INERGEN or other

  • AUTOMATIC FIRE DETECTION AND ALARM SYSTEM

  • A. CONVENTIONAL TYPE
  • B. ANALOG ADDRESSABLE TYPE
  • C. MICROPROCESSOR BASED

Victory Series fire alarm control panel are designed for use in premises requiring automatic fire detection.

Victory Series fire alarm control panel are designed for automatic fire detection & has sounder circuits with total evacuation switch.

  • Bank
  • Hotels
  • Market Complex
  • High Rise Building Theatre
  • Factories
  • Godowns
  • Warehouse
  • Shops
  • Railways
  • Ships
  • Diagnostic Centres
  • Record Rooms
  • Input Voltage :220V AC/50HZ
  • Auxiliary Power :24V DC ( Battery)
  • Battery :12 V7AH X2
  • Alarm :Warbling 110 Db
  • Power Consumption :Stand by 300 MA, Alarm 1.3 AMP
  • Alarm :95 AB AT 1 Mtr
  • Fuse Rating :1.5 AMP
  • Cable :1.5 SQ. MM. 2 Core Copper,Armoured
  • Lamp (Indicator) : LED's
  • Optional :With auto dialer

  • ADRESSABLE FIRE ALARM PANEL

FIRE SENSORS
  • 1. Ionization Smoke Detector
  • 2. Optical Smoke Detector
  • 3. Heat Detector
  • 4. Linear Heat Detector
  • 5. CO (Carbon Monoxide) detector
  • 6. Beam Detector
  • 7. Flame Detector
  • 8. Makes : Apollo (UK), System Sensor (USA)
EXTERNAL ALARM (HOOTER)
  • * Gives loud warbling type alarm, 90 db-110 db output.
  • * Self - oscillating amplifier circuit.
  • * Low current consumption
MANUAL CALL POINT
  • * Heavy Duty Switch contacts.
  • * Hammer for breaking of glass.
  • * Powder coated.
  • * Built - in LED to show actuation of the switch.
REMOTE INDICATOR
  • * Low power consumption
  • * Bright LED indication lamp.
CCTV CAMERA
  • * With all accessories


MOISTURE METER

  • DIGITAL ELECTRONIC MOISTURE METER

    MODEL – UTOPIA

The Digital Moisture Meter measures the moisture directly in percentage of the contents in food Grains, Tea, Wood, Chemicals etc. It is a robust and hand held equipment with rechargeable batteries.


The principal followed in controlling this vital element of moisture is by measuring changes in the electrical properties of the sensing materials due to interaction with water molecules.

Tea, Timber, dried Leaves, Sugar, Chemical, Paper, Yarn, Jute, Textiles, Fur, Powdered Milk, Tobacco, Coffee, Ayurvedic Formulation, Rice, Wheat, Cereal, Plywood, Wood Dust/Chips, Spices, Boards, lnsens Stick, Wool Dried Roots, Malt Powder, Fertilizers, Oil Seeds, Soil, Cement, Concrete, Salt, Bentonite, Baggasse.

  • Range :0-80% Moisture Content
  • Power :in - built, rechargeable batteries.
  • Operating Temp. (Ambiance) :0°C to 70°C
  • Battery Charger :Included
  • Low Battery Indication :Provided
  • Instrument carrying case :Provided
  • Sensor (any one) :1) Cup Electrode 2) Needle Electrode 3) Surface Electrode
  • Dimension :80mm x 145mm x 30mm
  • Display :Digital LCD
  • Detection Principle :Capacitive (Di electric)